Categories

Impresum

PROBUS K.I.G d.o.o.
Kutinska 15, N.S.P.
HR-44202 Sisak
CROATIA
tel. +385 44743190
fax. +385 44743191
email: This email address is being protected from spambots. You need JavaScript enabled to view it.



HI 98312 - Dist ® 5 tester for EC / TDS / Temperature

2820-2507.jpg2820-2507.jpg

  • Waterproof and it floats!

  • High accuracy

  • Automatic calibration and temperature compensation

  • HOLD function

  • BEPS (Battery Error Prevention System)

137,50 €
Sales price without tax 110,00 €
Tax amount 27,50 €
Description

When the original DiST® (Dissolved Solids Tester) was first introduced, conductivity and total dissolved solids measurements became easy and affordable. The DiST's ease of use, in combination with its affordability made it the standard in EC and TDS measurement. HANNA continues the standard in EC and TDS testing with the DiST®6.

This tester includes features such as: a replaceable graphite electrode, adjustable TDS ratio, °C or °F measurement, Automatic Temperature Compensation (ATC) with adjustable β, battery level indicator, stability indicator, automatic shut-off and automatic calibration.

The graphite conductivity electrode provides greater accuracy because it resists contamination by salt deposits in the sample.

All of these features are packed in a floating, waterproof casing. This 3-in-1 tester is unmatched in EC/TDS/ temperature measurements.

Order Information:
HI 98312 (DiST 6) is supplied with HI 73311 EC/TDS probe, HI 73128 probe removal tool, batteries and instructions.

 

Specifications

Area :
EC
: 0 to
20.00 mS/cm
TDS
: 0 to 10.00 ppm

Temperature :
0.0 to 60.0 ° C

Resolution :
EC
:
0.01 mS/cm
TDS
: 1 ppm

Temperature
: 0.1 ° C.

Accuracy @ 25 ° C :
EC : ± 2% of the measuring range
TDS : ± 2% of the measuring range

Temperature
: ± 0.5 ° C

Calibration :
EC : Automatic, the first point at
12.88 mS/cm ili 6,44 g/L (ppm)

TDS conversion factor : adjustable from 0.45 to 1.00

Temperature compensation : Automatic ß adjustable from 0.0 to 2.4% / ° C

Electrode : HI 73127 pH electrode changer (incl.) fixed ORP sensor

Power Supply : 1.5V (4) batteries for 100 hours

Self-Exclusion : After 8 minutes inactivity

Operating Conditions : 0 to 50 ° C (32 to 122 ° F); RH max 95% non-condensing

Dimensions : 163 x 40 x 26 mm

Weight : 100 g

Accessories

 HI 70030P

 12880 µS/cm (µmho/cm), 25 x 20 mL bags

 HI 7030L

 12880 µS/cm (µmho/cm), 1 x 500 mL bottle

 HI 70031P

 1413 µS/cm (µmho/cm), 25 x 20 mL bags

 HI 7031L

 1413 µS/cm (µmho/cm), 1 x 500 mL bottle

 HI 70032P

 1382 ppm (mg/L), 25 x 20 mL bags

 HI 7032L

 1382 ppm (mg/L), 1 x 500 mL bottle

 HI 70442P

 1500 ppm (mg/L), 25 x 20 mL bags

 HI 70038P

 6.44 ppt (g/L), 25 x 20 mL bags

 HI 73128   Tool for replacement of electrodes
 HI 73311  Spare electrode for conductivity and TDS

 

Download

 

no files for download.

 

 

HACCP thermometers

 

Termometri

HACCP catalogue <<< click

Hanna Checker!

first low cost digital water tester


www.prochecker.hr

Temperature Data Loggers

Microlite - low-cost temperature data logger


CATALOGUE <<< click